Add to Cart
Weight 250kg Temperature Humidity Chamber Constant Temperature And Humidity Chamber
Product Usage:
Mainly for the testing of electronic components, industrial materials, finished products in the R & D, production, inspection of all aspects of the test provide constant damp heat, complex high and low temperature alternating test environment and test conditions, suitable for electronic appliances, communications, chemicals, hardware, rubber, furniture , toys, scientific research and other industries.
Implementation and satisfaction criteria:
GB/T2423.1-2001 IEC60068-2-1.1990 GB11158
GB/T2423.2-2001 IEC60068-2-2.1974 GJB150.3
GB/T2423.3-93 GB10589-89 GJB150.4
GB/T2423.4-93 GB10592-89 GJB150.9
Temperature and humidity control range:
Product advantages:
Technical Parameters:
Model | JD-8001J-150 | JD-8001J-225 | JD-8001J-408 | JD-8001J-800 | JD-8001J-1000 |
Inner box size (W*H*D)mm | 500*600*500 | 500*750*600 | 600*850*800 | 1000*1000*800 | 1000*1000*1000 |
Carton size (W*H*D)mm | 740*1700*1310 | 740*1850*1410 | 840*1950*1610 | 1240*2100*1610 | 1240*2100*1810 |
Inner box volume | 150L | 225L | 408L | 800L | 1000L |
Temperature and humidity range | Low temperature range: -70 ° C; high temperature range: 180 ° C; humidity range: 20% RH - 98% RH | ||||
Temperature and humidity control accuracy | Temperature control accuracy: ±0.2 °C; humidity control accuracy: ±2.0% RH | ||||
Temperature and humidity uniformity | Temperature uniformity: ± 2 ° C; humidity uniformity: ± 3% RH | ||||
Heating time | -70℃~ +180℃,average3℃/min | ||||
Cooling time(min) | 180℃ 2.5℃/min 100℃ 2℃/min 18℃1.5℃/min -50℃ 1℃/min -70℃ | ||||
Power supply(kw) | 7.5kw | 8.0 kw | 10 kw | 11 kw | 12 kw |
weight(kg) | 250 kg | 300kg | 400 kg | 500 kg | 600 kg |
power supply | 3φ5w AC380 ±10% 50/60Hz |
Note:
1. The test method for uniformity of temperature and humidity distribution is measured according to the effective space of 1/10 distance from
the inner box.
2. can be customized according to customer size and size.
Freezing system:
A. Compressor: France imported full-tight compressor
B. Refrigerant: environmentally friendly refrigerant R404A
C. Condenser: Fin type with cooling motor
D. Evaporator: Fin type multi-section automatic load capacity adjustment
E. Other accessories: desiccant, refrigerant flow window, expansion valve
F. Expansion system: capacity control refrigeration system
Control System:
Original South Korea imported, full Chinese LCD 7 inch South Korea 880 display LCD touch panel, screen interactive input data, temperature and humidity can be programmed, curve display, set value / display value curve. Multiple alarms can be displayed separately. When a fault occurs, the fault can be displayed on the screen to eliminate the fault and eliminate the misoperation. Multiple sets of PID control functions, precise monitoring functions, and displayed on the screen in data format.
1. Controller specifications:
a. Accuracy: Temperature ± 0.1 ° C, humidity ± 1% RH
b. Resolution: temperature ± 0.1, humidity 1% R.H.
c. Temperature slope: 0.1 to 9.9 can be set
d. With upper and lower limit standby and alarm function
e. Temperature and humidity input signal selection PT 100Ω×2 (dry ball and wet ball)
f. Temperature and humidity conversion output: 4 ~ 20MA
G. 6 group P.I.D control parameter setting, P.I.D automatic calculation, dry and wet ball automatic correction
2. Screen display function:
a. Touch input, on-screen display options
b. Temperature and humidity setting (SV) and actual (PV) value are displayed directly (in English)
c. can display the current execution program number, the number of times, the remaining time and the number of cycles
d. Operation cumulative time function
e. The temperature and humidity program setting value is displayed in a graphical curve with real-time display program curve execution
function.
f. With separate program editing screen, directly input temperature and humidity and time
3. Program capacity and control functions:
a. Program group that can be used: up to 100 groups
b. Usable memory capacity: a total of 5000SEGMENTS
c. Repeatable execution of commands: up to 9999 times per command
d. The production of the program is interactive, with editing, clearing, etc.
e. SEGMENTS time setting 0~530Hour59Min
f. With power-off program memory, automatically start and continue to execute program function after power-on
g. Display the graph curve in real time during program execution
h. With date, time adjustment function
i. Button and screen lock (LOCK) function
surroundings:
(1). Allowable temperature range 0~35°C
(2). Performance guarantee range: 5~35°C
(3). Relative humidity: no more than 85%
(4). Atmospheric pressure: 86 ~ 106Kpa
(5). There is no strong vibration around.
(6). Direct sunlight or direct exposure to other heat sources
(7). Natural drainage outlet: ※ There shall be no bulge in the middle of the drainage pipe, and the floor of the house shall not have extreme inclination.
Power supply: single-phase power 9.5KW 380V 50HZ